User Manual 21 June 2001 Consoleerver S
6address. The network card must be connected to a network that uses TCP/IP. Devices connected to the network card must be at 10 Mbits (no auto–nego
74.0 Installation Instructions 4.1 Items in the Shipping Container a) ConsoleServer 3200 user manual b) User and Sys Admin Quick Reference Cards c
8the unit. Alternate power cords are available for all national connector standards. The standard AC power module has dual inputs. The DC power mo
94. Firmly seat the adapter in the serial port. Screw down the adapter to secure it to the serial port. 5. Insert one end of the serial cable in
105.0 Connecting Equipment to the ConsoleServer 3200 When connecting devices to the ConsoleServer 3200, be sure to use Lightwave Communications cab
115.2 Network Card The network card runs at 10 Mbits, half-duplex, with no auto-negotiation. The device used to connect the ConsoleServer to the ne
125.4 Device Card The ConsoleServer 3200 is designed so that the default device port communications settings will match the communications settings
13Standard DB9 or DB25 installation: Materials: • ConsoleServer 3200 device port • device with RS-232-C serial console port • RJ45-terminated Cat
14ConsoleServer 3200 Adapter Quick ChecklistHP9000SGI(Origin,O2, Octane, Onyx2)AdapterDB9-RJ45200.0070Terminal CableRJ45-RJ45 CableRJ45-RJ45 CableAda
15 SWITCHBBBBBBBBBDDCCDDDDDDCCCCCCDEVICEAAADEVICE CONTROLAAAAAADEVICE DEVICE DEVICEDEVICEDEVICEDEVICEBBBBDDDD0ICCCCAAAATERMINALTERMINALSWITCHTERMINAL
Lightwave Communications, Inc. 100 Washington Street Milford, CT 06460 USA (800) 871-9838 • (203) 878-9838 • Fax: (203) 874-0157 Email: info@lightwa
166.0 ConsoleServer 3200 Administration The following section outlines the administration functions and commands. The administration functions and
17The serial terminal will display the following text at power-up: ConsoleServer3200 Boot V1.76 Copyright 2000 by Lightwave Communications, Inc.
186.1.2 Logging In, Network Connection UNIX_MACHINE# telnet 172.16.1.200 5000 Connecting to 172.16.1.200 port 5000... Escape sequence is ^] Welc
19LOGGED OUT HELP SCREEN LCI3200>>help ConsoleServer 3200 Sys Admin Command List [] - optional <> - parameter must be specified
20 1 will refer to the netterm subsystem and 2 will refer to the network subsystem on the card F1 - G1 switch cards (do no
21INFO - (no abbreviation) LCIUPDATE - (no abbreviation) LINESPERPAGE - LINESPP
226.2 Creating and Managing Users 6.2.1 Adding a User ID The ADDUSER command creates user IDs and assigns initial privileges. The following scre
23 Fig. 4 Device Port Numbering HELPFUL HINT: Make a diagram or spreadsheet of connections indicating connections between devices and the ConsoleSer
24 sys admin>>ADDUSER Number of available user records: 200 Number of users defined: 0 Enter user id | USER ID > tom Enter case sensitive pa
25 sys admin>>LISTUSERS 1: User id > PETE 2: User id > KEVIN 3: User id > TONY sys admin>>LISTUSERS /ALL 1: User id > PETE
1.0 Product Description ...
26 To delete a user ID using the record number, specify the number as a qualifier after the DELETEUSER command in the form DELETEUSER /N, where N is
27 sys admin>>terminal 1 Enter accepts present value T1: 0=9600, 1=19200, 2=38400, 3=57600 | BAUD RATE: 9600> T1: 0=1, 1=2
28 sys admin>>TERMINALS 1 Enter accepts present value T1: 0=9600, 1=19200, 2=38400, 3=57600 | BAUD RATE: 38400> T1: 0=1, 1=2
29The NETWORK command will either display the network settings of the installed network cards or change those settings depending on which command qua
30 sys admin>>NETWORK /ALL Enter accepts present value N-B: Enter IP address | 000.000.000.000> N-B: Enter Subnet Mask
31 sys admin>>NETWORK B Enter accepts present value N-B: Enter IP address | 000.000.000.000> 172.16.1.1 N-B: Enter Subnet Mask
32 sys admin>>MODEM Enter accepts present value Init string | > ATB2H0 Save changes and update modem card? Yes or No: No>yes Modem card
33 sys admin>>CONNECTIONS Terminal Connection List 01 KEVIN 01 SERVER ( Monitor mode ) 02 00
346.7.2 LISTCARDSLISTCARDSLISTCARDSLISTCARDS Command Sys admin>>LISTCARDS Installed cards Slot A : <card not installed> Slot B : Termin
356.7.4 INFOINFOINFOINFO Command sys admin>>INFO A Slot A1: Modem: No Active Call Timeout = 1 mins. Current Modem State: in command mode Mod
7.0 User Access and Interface...
36• The primary IP information, including: IP address, subnet mask, and gateway • The secondary IP information, including: destination address, sub
37no time/date stamp on system activity. If a time/date stamp is required, it must be provided by the system capturing the data output. Connection
386.8.1 LINESPERPAGELINESPERPAGELINESPERPAGELINESPERPAGE Command sys admin>>LINESPERPAGE Lines per page set to 22 sys admin>LINESPERPAGE
39 The BREAK command allows the sys admin to disconnect a user from the device port to which they were connected if they are in monitor, listen, or d
40The TELNETTIMEOUT command allows the sys admin to define the amount of time that a network card may have an idle telnet session before breaking the
41the ConsoleServer 3200 to restore the system settings. It is not possible to use the BACKUP and RESTORE commands from a network sys admin session.
42To change the system prompt to the default (LCI3200>), use the command PROMPT /DEFAULT. 6.12 Updating the ConsoleServer 3200 Software As new
437.0 User Access and Interface 7.1 Terminal Card Each terminal card has four (4) RJ45 connector ports to which a terminal may be attached, giving
44 At power-up, the network card does not respond to network connect requests until the control card has completed its system initialization. Once t
45sections above). This indicates that the user is not currently logged in and that no servers may be reached through the ConsoleServer 3200. The p
11.0 Product Description The ConsoleServer 3200 (also referred to as the CS 3200) is one of the most versatile network administration tools availabl
46MONITOR (A.K.A. DEVICE) MODE HELP: F1 - Display Help Screen (VT100 mode) F2 - Display Pull Down Menu (VT100 mode) TTY COMMANDS: (MONITOR
477.5 Logging In and Changing Passwords F2 PULL-DOWN MENU SHOWING INITIAL MENU CHOICES ┌─────────────────┐
48password and press <ENTER>. The ConsoleServer 3200 will then prompt the user for the new password by displaying the prompt PLEASE ENTER NEW
49are logged in, which devices they have currently selected, and which mode they are in. Users may also view this information by selecting DISPLAY C
50not have permission to access a server, the ConsoleServer 3200 will display the message NO ACCESS TO DEVICE CHANNEL, and the connection will not be
51F2 PULL-DOWN MENU TO LISTEN TO A DEVICE PORT PART 2 ┌───────────────────────────────────────────────────┐ │
527.10 Direct Mode F2 PULL-DOWN MENU SHOWING DEVICE (A.K.A. MONITOR) MODE OPTIONS ┌─────────────────────────┐
53software used. It is also recommended that the user avoid combinations of the <CTRL> key and other keys, as these combinations are usually r
54When at the monitor mode prompt, the user may view the contents of the buffer using the commands TOP, BOTTOM, NEXT, PREVIOUS, FORWARD, and REVERSE,
55FORWARD FORWARD N LINES skip forward N lines in buffer REVERSE REVERSE N LINES skip back N lines in buffer The commands FORWARD and REVERSE must
21.1 Features • Connect up to thirty-two RS-232C compatible console ports • No break sent to attached servers at any time unless sent by a user •
568.0 The Break Generation Sequence F2 PULL-DOWN MENU TO CHANGE BREAK SEQUENCE ┌──────────────────────────┐
579.0 Displaying System Information F2 PULL-DOWN MENU TO DISPLAY SYSTEM INFO ┌─────────────────┐
5810.0 Front Panel Display Information: The up/down arrow keys are used to scroll through multi-page displays. Lightwave Communications, Inc.
59Panel 3 (press down) Panel 4 (press down) The next series of panel shows the port number along with the name of the device connected to that p
60Panel 7 (press down) Panel 8 (press down) Panel 9 (press down) The next series of panels displays the inventory of cards that are installed in
61Panel 12 (press down) The last panel displays the status of the power supplies. Panel 13 (press down)
62Appendix A – Adapter & Connector Pinouts Title:Size:Part NumberRev:SheetFile:System:AA0101ofTerminal / Device RJ45 Connector PinoutsConsoleServ
63Title:Size:Part NumberRev:SheetFile:System:AA200d0066.vsd 0101ofRJ45 Receptical to DB25M Adapter200.0066ConsoleServer 32002DB25MALE3456782032786514
64Title:Size:Part NumberRev:SheetFile:System:AA200d0067.vsd 0101ofRJ45 Receptical to DB25F Adapter200.0067ConsoleServer 32002DB25FEMALE34567820327865
65Title:Size:Part NumberRev:SheetFile:System:AA200d0070.vsd 0101ofRJ45 Receptical to DB9F Adapter200.0070ConsoleServer 32001DB9FEMALE234567812345678R
32.0 System Overview 2.1 Connect Up to Thirty-two RS-232C Compatible Ports The ConsoleServer 3200 is plug-compatible with any RS-232C device. Thes
66
67Appendix B – Field Update of Console Server 3200 Flash Memory B.1 Introduction The system administrator may desire to update the software held in
68application code version, which is listed first) is greater than 1.70, then Kermit may be used to transfer the binary update files; otherwise, Xmod
69to be updated at this prompt. See page XX for slot letter ID’s. For most cards, the processor number will be 1; network cards have two processors
70 The tftp server must be specified by a numerical IP address. The file path and name on the server is specified after the IP address. local seria
71 B.6 Ending the Flash Update Slot (letter) Processor (number) Ex. C1 (exit to restart system): EXIT Starting system ConsoleServer 3200 Contro
72SWITCHBBBBBBBBBDDCCDDDDDDCCCCCCDEVICEAAADEVICE CONTROLAAAAAADEVICE DEVICE DEVICEDEVICEDEVICEDEVICEBBBBDDDD0ICCCCAAAATERMINALTERMINAL SWITCHTERMINAL
73 Appendix C – System Specifications C.1 Physical Width: 17.25 inches (43.82 cm) Depth: 14.75 inches (37.47 cm) Height: 5.25 inches
74C.4 Interface C.4.1 Terminal and Device Connector: RJ45 with adapters for EIA-standard connectors (DB9 and DB25) Specification: EIA-232 Maxi
75Appendix D -DC Power The DC power version of the ConsoleServer 800 must be installed in a restricted access location. Per the intent of the Natio
4 The modem card connects directly to an ordinary phone jack (RJ11) to interface with a telephone network. The sys admin may designate a modem initi
76 Input voltage: -48 VDC Minimum voltage: -40 VDC Maximum voltage: -60 VDC Maximum operating current: 1.5 A Maximum input surge
77The DC power source must be: • electrically isolated from any AC source • reliably connected to earth • capable of providing up to 100 Watts of
78Appendix E – Command Abbreviations Most, but not all, commands available on the ConsoleServer 3200 may be abbreviated. The following list outline
79Terminal, Network, and Modem Commands: command abbreviation bottom bo bye bye changepswd ch clear cl connections co devlist de direct dir diselect
80Appendix F – Hexadecimal ASCII Code Equivalent characters in italics are non-printing characters or signals. Hexadecimal Code Equivalent Characte
81 Hexadecimal Code Equivalent Character Hexadecimal Code Equivalent Character 40 @ 60 ` 41 A 61 a 42 B 62 b 43 C 63 c 44 D 64 d 45
82Index Abbreviations – 16, 19-20, 45, 76-77 Backing up system settings – 39-40 Breaks – 2, 5 editing generation sequence - 55 sending - 55 B
83 see also: User Network Card – 1-3, 5-6 checking settings – 34-35 connecting to – 42-43 idle timeout – 38-39 setting parameters – 27-30
84 directly interacting with device port – 51-52 editing break sequence - 55 editing direct mode escape sequence – 51-52 logging in - 46 log
53.0 System Components Each ConsoleServer 3200 consists of three major components: chassis, device cards, and access cards. 3.1 Chassis The chassi
Comments to this Manuals